Home Programs
|
Properties of the Small
Transformers Program

Languages |
English, French, German, Italian and
Spanish |
Units |
Metric and USA units |
Power range per phase at 50/60
Hz |
10kVA per phase |
Frequency range |
10Hz ...500kHz |
Input /Output voltage range and
form |
1V ...10kV, independent of the form (sine
wave, rectangular,...) |
Primary |
Max. 8 taps for the inputs and the outputs
in autotransformer operation mode. |
Secondary |
Max. 8 secondary, connected to the load
direct or via the rectifiers with R, RL or RC load, together with
autotransformer operation available |
Wire |
Cu- round and flat wires, with 3 insulation
grades |
Steels |
Cold rolled, grain oriented, Ne-Fe alloys,
ferrite, amorphous and powder |
Bobbins |
Single section, double section and single
section without flange, open and closed The cores and bobbins,
which do not exist in the core data pools, can be created by
user. |
Case |
Potted and not potted |
Core assembly |
Alternately stacked EI,UI,..., C-cores,
welded, ready cores, modulus cores and alternately stacked
strips |
Winding assembly |
Primary inside or outside, alternately
windings 50%/100%/500%, 33%/66%/66%/33% and
25%/50%/50%/50%/25% |
Cooling channel |
One cooling channel, only in the front and in the back
of the winding, between the primary and the secondary |
Ventilation |
Max. 5m/sec |
Impregnation |
Dry, one component varnish and 2 components
varnish, under vacuum. |
Chassis |
Wood, printed board, metal |
Duty cycle operation mode |
Min. time 5 seconds, with 2 times and 2
loads |
Criterion of the design: |
Regulation of the output voltage: 1% to
150% or Temperature rise in nominal, short-circuit or duty
cycle operation: 10°K ...250°K |
Induction |
Optimized in accordance with the temperature
rise, no-load operation and the inrush current |
Ambient temperature |
-100°C ... 120°C |
Core families data pool |
EI, EE,..., UI, LL,..., 3PhEI, C-cores, EC, ETD, RM, PM,
P, EFD, EPC, RS, DS, PQ,... The cores and bobbins, which do not
exist in the core data pools can be created by user. |
Design mode |
In this mode the program designs in accordance with the
input data. |
Test and simulating mode |
In this mode the user can change manually the turns,
wire sizes, loads, input voltage, frequency, duty cycle, steel,...
and recalculate the transformer. |
Typical applications |
DC/DC converters : The program supports
flyback, forward (simultaneous too) and all transformers, driven by
the "impressed" input voltage or "impressed" input current
(bridge, push-pull, resonant,... converters)
Battery chargers, Adapters: The program
supports the operation of the one and three phase transformers with
the rectifiers on the R, RL or RC load
Inherently short-circuit proof, not-inherently
short-circuit proof and not short-circuit proof
transformers
Medical transformers Control
transformers Universal transformers or universal
autotransformers Autotransformers Motor starting transformers
or autotransformers Voltage transformers Current
transformers Toy transformers Bell transformers Audio
transformers Transmitters K-factor transformers
|
|